Application for type approval for devices containing radioactive substances and installations for the generation of ionising radiation Unfortunately this specification of service has not yet been completely translated.

If you wish to manufacture devices containing radioactive substances or installations for the generation of ionising radiation which may be operated without a licence or notification, you may apply for a type approval.

The Federal Office for Radiation Protection (BfS) is responsible for issuing type approvals for devices containing radioactive substances and systems for generating ionising radiation. If you acquire a type approval for a device or installation, you can use it without a permit or notification.

With the granting of the type approval, the BfS confirms that the tested type meets the legal requirements for radiation protection. The type approval covers the entire design. No further special approval or testing is required for individual devices.

You submit your application for type approval for devices in which radioactive substances are inserted as well as for facilities for the generation of ionising radiation to the BfS.

Notice:
The BfS grants the design approval for a maximum of 10 years. Upon application, you can have a granted design approval extended.


When applying, you must submit:

  • Description of the design of the device and its application
  • Drawings (compilations, exploded views if applicable) with associated material specifications, in particular for shielding and source supports
  • Information on the emitter, in particular drawings of the emitter and information on the radiation classification in accordance with DIN EN ISO 2919, certificates or information on the UKP laser with performance data
  • information on permissible operating conditions and the intended duration of use
  • Operating instructions in German language
  • Quality control concept
  • take-back concept
  • current excerpt from the commercial register
  • Certificate of good conduct for presentation to the authorities from the persons representing the applicant (e.g. management)
  • Proof of qualification of the technical manager of the production
  • Proof of qualification of the experts to be appointed for quality control in production
  • Form for administrative data
  • depending on the application: form for devices or form for plants

Related Links

  • Antrag auf Bauartzulassung für Vorrichtungen, in die radioaktive Stoffe eingefügt sind, sowie für Anlagen zur Erzeugung ionisierender Strahlung
  • Formblatt zu administrativen Angaben
  • Formblatt zu technischen Angaben für Vorrichtungen, in die radioaktive Stoffe eingefügt sind
  • Formblatt zu technischen Angaben für Anlagen zur Erzeugung ionisierender Strahlung

Preconditions

Applications for approval may be submitted by

  • Legal persons who place a device or system on the market in Germany
    • manufacturers or
    • Persons and organisations who supply the device or system to Germany or have it supplied to them.

Further requirements:

  • They must guarantee by means of a quality control that only devices are manufactured or brought into Germany which correspond to the tested type.
  • The quality control must be supervised by an expert.

Related Links

  • §§ 45 49 Gesetz zum Schutz vor der schädlichen Wirkung ionisierender Strahlung (Strahlenschutzgesetz StrlSchG)
  • §§ 16, 17, 24 - 26 Verordnung zum Schutz vor der schädlichen Wirkung ionisierender Strahlung (Strahlenschutzverordnung StrlSchV)

Related Links

  • Allgemeine Informationen zum Verfahren auf der Internetseite des Bundesamts für Strahlenschutz
  • Vorschlag der Strahlenschutzkommission für Anforderungen an die Bauartzulassung von Vorrichtungen, in die radioaktive Stoffe eingefügt sind, auf der Internetseite des Bundesamts für Strahlenschutz
  • Angaben zur Bestimmung des Sachverständigen zur Überwachung der Qualitätskontrolle auf der Internetseite des Bundesamts für Strahlenschutz

You must submit the application for type approval in writing to the Federal Office for Radiation Protection (BfS).

  • You download the application forms from the BfS website and fill them out.
  • You must select one or more authorised experts to supervise the quality control. Experts are persons who have knowledge and experience in radiation protection as well as knowledge of the design and construction of the device in question. They may belong to their own or to other companies (e.g. TÜV) and must be independent in the performance of their activities. Experts monitor that no device is placed on the market whose design deviates from the desired approval. You must inform the BfS of the experts and their qualifications when submitting the application.
  • You send the completed and signed application forms together with the other required documents by post, fax or e-mail to the BfS. Further documents can be sent by e-mail or via a filetransfer portal.The BfS will check your application. In the case of devices containing radioactive substances, the Federal Institute for Materials Research and Testing (BAM) is involved.
  • If all requirements are met, the BfS issues the type approval and awards a type mark. The approval certificate and the determination of the experts will be sent to you by mail with a notice from the BfS.